狀況說明:

開啟ESX 4.1內的某VM,發現常時間停在95%,待一段時間後,無法開啟Console,出現「unable to connect to the mks ...」

解決方法:

  1. With vSphere Client, connect to the host or the VC server that controls the host.
  2. Click on the host and go to the Configuration tab.
  3. Click on Security Profile.
  4. Click on Properties in the Services table.
  5. Start ESXi Shell and SSH services.
  6. Open a SSH session to the host.
  7. Execute /sbin/services.sh restart. This will restart all agents. The vSphere Client or the vCenter server will lose connection to the host. Reconnect! The VM may show as (invalid).
  8. Find the PID of the process by typing ps|grep “<VMName>”. The second number before the name of the VM is the PID.
  9. Kill the process by typing kill -9 <PID>.
  10. Go to /vmfs/volumes/<DataStoreName>/<VMName>.
  11. Delete the swap file by typing rm –r <SwappFileName.vswp>
  12. In vSphere Client right click the VM and select Remove From Inventory.
  13. Browse the data store, open the VM folder, right click on the .vmx file and select Add to Inventory.
  14. Power On the VM.

 Reference:http://www.konkotech.com/blog/?p=72 


masterman 發表在 痞客邦 留言(1) 人氣()

狀況說明:

昨日發現一台esx 4.0主機其中一顆硬碟故障(做RAID 1),利用clone vm方式也無法將vm備份出來。

解決方法:

1.利用再生龍,將整顆硬碟備份成映像檔,然後測試異機還原,出現錯誤訊息如下:* vsd-mount .................................................... [Failed]

masterman 發表在 痞客邦 留言(0) 人氣()

主要該台主機安裝了IBM DS Storage Manager軟體
 
此服務與該軟體所用到的Port相衝突,移除該軟體後,該服務已正常。

 


masterman 發表在 痞客邦 留言(0) 人氣()

狀況說明:

ESXi 5.1具有無共用儲存就可以達到vMtion的新功能,但在vSphere Client試不出來。

解決方法:

原來VMware將此功能設計在Web Client中。

Reference:http://plain-virt.blogspot.tw/2012/09/vsphere-51-vmotion-with-no-shared.html

masterman 發表在 痞客邦 留言(0) 人氣()

有關VMware Data Preotection的 FAQ

Reference:http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2016565


masterman 發表在 痞客邦 留言(0) 人氣()

狀況說明:

無法備份Server 2008 R2作業系統的VM,出現「 E10055:Failed to attach disk.“」錯誤訊息

解決方法:

To work around this issue configure disk.EnableUUID to false.
 

masterman 發表在 痞客邦 留言(0) 人氣()

解決方法:

1

  輸入「-locale en_US」


masterman 發表在 痞客邦 留言(0) 人氣()

狀況說明:

將vCenter成功升級至5.1後,欲透過update manager升級至ESXi 5.1,畫面顯示「Software of system configuration of host <hostname> is incompatible. Check scan results for details.

解決方法:

將ESXi主機重新開機後,便可透過update manager升級。

 

masterman 發表在 痞客邦 留言(0) 人氣()

狀況說明:

安裝過程中,出現下圖之錯誤訊息。

  SSO2  

 

解決方法:

masterman 發表在 痞客邦 留言(0) 人氣()

狀況:

如AD未特別設定,每位domain users只能加入10台電腦到網域內

Reference:http://support.microsoft.com/kb/251335/zh-tw


masterman 發表在 痞客邦 留言(0) 人氣()

進行ESXi升級之前,建議將ESXi設定黨做備份,避免升級異常,而無法回復。

Reference:http://www.weithenn.org/cgi-bin/wiki.pl?VMware_Host_Profiles_Backup#Heading4

                   http://communities.vmware.com/thread/406335?tstart=50


masterman 發表在 痞客邦 留言(0) 人氣()

CAT-1
目前未被TIA/EIA承認。以往用在傳統電話網路(POTS)、ISDN 及門鐘的線路。
CAT-2
目前未被TIA/EIA承認。以往常用在 4 Mbit/s 的令牌環網路。
CAT-3

masterman 發表在 痞客邦 留言(0) 人氣()

Reference:http://www.sonicwall.hk/index.php?case=archive&act=show&aid=45


masterman 發表在 痞客邦 留言(0) 人氣()

檔案系統格式查詢

語法:df -T

         df -h -T

其它查看檔案系統的方式

  • cat /etc/fstab
  • cat /etc/mtab

Reference:http://blog.longwin.com.tw/2010/08/linux-df-file-system-format-2010/


masterman 發表在 痞客邦 留言(0) 人氣()

Reference:http://leeilu.blogspot.tw/2011/10/blog-post.html


masterman 發表在 痞客邦 留言(0) 人氣()

Close

您尚未登入,將以訪客身份留言。亦可以上方服務帳號登入留言

請輸入暱稱 ( 最多顯示 6 個中文字元 )

請輸入標題 ( 最多顯示 9 個中文字元 )

請輸入內容 ( 最多 140 個中文字元 )

reload

請輸入左方認證碼:

看不懂,換張圖